Nearly ten APC Back-UPS died after a year: I'm trying Eaton

My take: Nearly ten APC Back-UPS BX950MI-FR, the same story: dead after about a year. I'm testing Eaton instead, and so far, so good.
I no longer recommend the APC Back-UPS BX950MI-FR. I have been through nearly ten of them, and they all followed the same pattern: after about a year, they stopped working. By the end, they could not even absorb a micro-outage, a cut of a fraction of a second, which is the very thing a UPS (uninterruptible power supply) is there for. That is my experience with nearly ten units, not a lab test: other owners may have had better luck. But nearly ten identical endings are enough for me to replace them.
What APC promises
On paper, the BX950MI-FR has a lot going for it. Schneider Electric, which owns APC, lists it as a line-interactive UPS: it corrects small voltage swings without switching to its battery. It delivers 950 VA or 520 W, on four French outlets, with an approximated sine wave. Its datasheet rates the battery at 3 to 5 years and the unit's warranty at 2 years, repair or replacement.
Two details are worth knowing before you buy one. Schneider lists its battery as not user replaceable: swapping it can expose live parts, so only qualified service staff should do it. And the datasheet lists no USB port, so this model cannot tell a computer or a NAS to shut down before the battery runs out. Schneider plans to stop making it on February 1, 2027, and recommends the BXR950MI-FR in its place.
What I'm testing instead
To replace the APC units, I have been testing an Eaton 3P Ellipse 700 USB FR (reference 3P700UF) for six months as of November 2026. So far, so good. To be continued.
Per Eaton, it delivers 700 VA or 420 W. Of its four French outlets, three run on battery with surge protection, and the fourth has surge protection only. Two USB charging ports (one USB-A, one USB-C) sit next to a HID-compatible USB port, the standard one computers and NAS recognize as a UPS, with its cable in the box and Eaton's UPS Companion software for a clean shutdown. The battery, a 12 V, 7 Ah sealed lead-acid block, is replaceable. There is no fan; Eaton gives a noise level under 25 dB at one meter. Its brochure states 3 years of warranty on the electronics and 2 on the battery.
One point goes to APC on paper. Eaton lists the 3P's topology as offline: it switches to battery as soon as the voltage leaves its range (184 to 264 V, adjustable to 161 to 284 V), where a line-interactive unit corrects the voltage first. The more elaborate design is the APC one. In my case, it is also the one that kept giving up.
What to check before you buy a UPS
- A battery you can replace yourself. A UPS battery wears out by design. When it is sealed in, a worn battery means a new UPS.
- Voltage regulation, sold as AVR (automatic voltage regulation) or line-interactive, if your power often dips. A standby unit handles those dips on battery.
- A USB data port, not just charging ports. With it, a Synology NAS running DSM can watch the UPS (Control Panel, Hardware & Power, UPS) and enter Standby Mode before the battery runs out: services stop and volumes unmount, so nothing is half-written when the power goes. It can even share that UPS over the network with other Synology NAS.
- A real test. Synology itself advises simulating an outage before relying on the setup: unplug the UPS from the wall and watch what happens.
If a BX950MI-FR protects one of your machines, run that test with nothing critical plugged in: unplug it from the wall and see whether it holds.
Drafted with Claude, Anthropic's AI, from my take. Reviewed and owned by me.